Dissolved Oxygen Analyzers/Transmitters,
2wire / 4 wire with Hart protocol

The OBM-165H is a 2-wire type (24VDC power supply) dissolved oxygen transmitter (for Low-Concentration Measurement) housed in a robust, die-cast aluminum enclosure suitable for installation out in the field.

This model is equipped with a wide range of useful features, such as HART communication.

Features

  • HART communication (version 7) supports the transmission of digital data such as DO measured value, temperature measured value, and equipment status commands.
  • CE mark compliant.
  • Freely adjustable transmission output range.
  • When maintenance mode is enabled, the "ST-BY" indication is on. In maintenance mode, the output signal is held at the value which was set before the mode was enabled.
  • The instrument can also be configured to automatically return to measurement mode. This feature is especially useful when the instrument is inadvertently left in maintenance mode.
  • The instrument is equipped with a burn-out function. When the self-diagnostics function detects an error in the measurement system, such as a computer error or the failure of the temperature compensation resistor, the burn-out function provides notification of the problem by causing the transmission output to go off- scale (upper or lower limit).
  • The instrument automatically judges the quality of electrode characteristics during calibration, and provides diagnostic information in the form of error messages.
Dissolved Oxygen Analyzers/Transmitters, 2wire with Hart protocol
Dissolved Oxygen Analyzers/Transmitters, 2wire with Hart protocol

The OBM-167H is a 2-wire type (24VDC power supply) dissolved oxygen transmitter housed in a robust, die-cast aluminum enclosure suitable for installation out in the field.

This model is equipped with a wide range of useful features, such as HART communication.

Features

  • HART communication (version 7) supports the transmission of digital data such as DO measured value, temperature measured value, and equipment status commands.
  • CE mark compliant.
  • Freely adjustable transmission output range.
  • When maintenance mode is enabled, the "ST-BY" indication is on. In maintenance mode, the output signal is held at the value which was set before the mode was enabled.
  • The instrument can also be configured to automatically return to measurement mode. This feature is especially useful when the instrument is inadvertently left in maintenance mode.
  • The instrument is equipped with a burn-out function. When the self-diagnostics function detects an error in the measurement system, such as a computer error or the failure of the temperature compensation resistor, the burn-out function provides notification of the problem by causing the transmission output to go off- scale (upper or lower limit).
  • The instrument automatically judges the quality of electrode characteristics during calibration, and provides diagnostic information in the form of error messages.
  • The system is equipped with a salinity compensation function.